Inputs; Can Bus; D-In/D-Out/F1/F2; Calculation Channels - Parker Service Master CONNECT Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical Data
11.4

Inputs

11.4.1 CAN Bus

Designation
Number
Plug
Voltage
Power supply
Fuse
CAN X
CAN Y
Baud rate (Parker CAN)
Baud rate (external CAN)
Sensors, CAN X
Sensors, CAN Y
Scanning rate, P-channel, 1
Scanning rate, P-channel, 2

11.4.2 D-IN/D-OUT/F1/F2

Designation
Number
Plug
Voltage
Power supply
Input
Active High
Active Low
Accuracy
D-IN input impedance
Frequency range
Load current, D-OUT

11.4.3 Calculation Channels

Designation
Number
Connection
Functions
128
Properties
2
5-pin, M12×1, panel connector
+18...+24 V
DC
Max. 250 mA
Short circuit
120 Ω terminating resistor be-
tween PIN 4 and PIN 5
120 Ω terminating resistor be-
tween PIN 4 and PIN 5
500 kBit/s
10, 20, 50, 125, 250, 500, 800,
1000 kBit/s
Max. 24 (Parker CAN)
Max. 24 (Parker CAN)
Max. 5 (external CAN)
1 ms = 1,000 meas. values/s
2 ms (per network)
Properties
2
5-pin, M12×1, panel connector
+24 V
DC
80 mA
D-IN/D-OUT or F1/F2
> 3 V
Dc
< 1.4 V
Dc
≤± 0.1%
1 kΩ
0 ... 20 kHz
max. 20 mA
Properties
4
Virtual
/,*,+,-,f´(t),Integral, sin, cos, tan, x^2, SQRT,x^y
Description
CAN X and CAN Y
SPEEDCON
connector
®
Per network
Per connection
Per network, CAN V+ to GND
No galvanic separation
No galvanic separation
Only at CAN-Y
CANX1 – CANX24
CANY1 – CANY24
Up to 4 sensors per network
From 5 sensors per network
Description
1 × D-IN, 1 × D-OUT or
1 × F1, 1 × F2
SPEEDCON
connector
®
Galvanically separated
Description
CALC-1, CALC-2, CALC-3, CALC-4
The Parker Service Master CONNECT V1.2/06/21 EN

Publicité

Table des Matières
loading

Table des Matières