2/ Manual mode

The left control knob allows to adjust the speed and the
right one to adjust the voltage (not linked to the main
parameter menu).
The Expert display mode allows to access to the chart
mode, in order to adjust the parameters (pre-gas, post-
gas in the case of 2T).

3/ Standard mode

In Standard Mode - The left control knob allows to
adjust the selected parameter (Thickness, Speed or
Current) and the right one the arc length.
In Standard Mode - Delay - The left control knob allows
to adjust the duration of the point and the right knob
the delay between each point
AUTOPULSE 320-T3
In manual mode, there is only one secondary parameter,
the self.
In Spot and Delay modes, the time parameters are
accessible from the single mode.
In Standard Mode - The push-button (C) allows access to
the welding position and the self.
The Standard Mode - 2T - Expert allows to access the
Chart (Pre-gas, HotStart, Crater Filler and Post-gas)