2.2
Intended Use
The GuardOne
®
Workstation is to be used only for the intended use described herein. The GuardOne
using air filtration technology and UV irradiation to create a working environment which minimizes the risk of cross-contamination under standard
laboratory working conditions. The GuardOne
operating manual is part of the inteded use. Any use beyond the intended is considered as misuse. All country-specific safety requirements for
operating electrical equipment in the laboratory must be observed.
WARNING!
Risk of misuse!
Misuse of the GuardOne
- Only install STARLAB spare parts and wear parts in the GuardOne
authorized by STARLAB results in malfunction of the GuardOne
to the sample material.
- Use the GuardOne
(Chapter 10 "Specifications" on page 48).
WARNING!
Danger due to property protection only!
The GuardOne
Workstation exclusively serves for process protection. There is no personal protection included.
®
- Do not use pathogens within the GuardOne
2.3
Safety Installations
Main power switch
The main power switch is also designed as an emergency stop switch. It is located at the rear of the top housing unit in the upper right corner.
Turning the main switch to position „0", results in the airflow and UV decontamination stopping immediately.
The GuardOne
®
Workstation is switched off. Electrical elements, such as the display, are de-energized.
Safety contact on the front door
To ensure that access to the inside is only possible with the UV lamp switched off, the lower segment of the front door is equipped with safety contacts.
At the same time, the safety contacts prevent the airflow from blowing when the front door is closed. The UV decontamination of the GuardOne
Workstation can only be started when the front door is closed. At the same time, closing the door means that the airflow stops working.
2.4
Responsibilities of the Operator
Operator
The operator is the person who operates the GuardOne
Operator obligations
In addition to the safety instructions in this operating manual, the operator has to observe the safety, occupational safety and environmental
regulations. The following applies in particular:
›
The operator must be aware of the applicable health and safety regulations. He has to identify hazards in a risk assessment that are caused
by the specific working conditions in the work area of the GuardOne
›
During the entire operating time of the GuardOne
current state of the regulations. If necessary, the operator has to adjust them.
›
The operator has to regulate and set the responsibilities for installation, operation, troubleshooting, maintenance and cleaning.
›
The operator has to ensure that all persons who handle the GuardOne
Additionally, the operator has to keep the staff trained and informed about dangers on a regular basis.
Furthermore, the operator is responsible for ensuring that the GuardOne
Therefore:
›
The operator must ensure that the maintenance intervals are observed.
Workstation exclusively serves for process protection. The compliance with all instructions in this
®
®
Workstation can lead to dangerous situations for persons and property.
Workstation exclusively within the specified conditions of use which are supplied in the specifications
®
Workstation.
®
Workstation for commercial, economic or research purposes.
®
Workstation, the operator has to check if these operating instructions comply with the
®
Intended Use/Responsibilities of the Operator
®
Workstation is a containment equipment
Workstation. The installation of spare parts and wear parts not
®
Workstation, contamination of the work environment, and damage
®
Workstation.
®
®
Workstation have read and understood this operating manual.
Workstation is always in perfect technical condition.
®
Safety
®
9
GuardOne
®
· Manual ·