36
9.1
ANTI-CONDENSATION SWITCH
1. Connect the anti-condensation switch to the wire harness located in the bottom left corner of your
appliance. Refer to the "WIRING DIAGRAM" section of your appliance's installation instructions.
2. Remove the nut and lock washer from the anti-condensation switch.
3. Install the anti-condensation switch through the switch plate, ensure locating tab is down and secure using
the lock washer and nut, as illustrated.
4. Flip the switch up for standing pilot (anti condensation) or down for intermittent pilot ignition.
f i r e - p a r t s . c o m
10.0
ADJUSTMENTS
10.1 PILOT BURNER ADJUSTMENT
Adjust the pilot screw to provide properly sized fl ame. Turn in a
clockwise direction to reduce the gas fl ow.
Check Pressure Readings:
Inlet pressure can be checked by turning screw (A) counter-
clockwise 2 or 3 turns and then placing pressure gauge tubing
over the test point. Gauge should read 7" (minimum 4.5") water
column for natural gas or 13" (11" minimum) water column for
propane. Check that main burner is operating on "HI".
Outlet pressure can be checked the same as above using
screw (B). Gauge should read 3.5" water column for natural
gas or 10" water column for propane. Check that main burner
is operating on "HI".
AFTER TAKING PRESSURE READINGS, BE SURE TO
TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO
NOT OVERTORQUE.
Leak test with a soap and water solution.
W415-1028 / A / 08.13.12
All manuals and user guides at all-guides.com
B
A
PILOT
BURNER
ELECTRODE
FLAME
SENSOR
FLAME MUST ENVELOP
UPPER 3/8" TO 1/2" OF
FLAME SENSOR
39.1A
PILOT SCREW