D. Assembling Extractor Housing
1
4
OM-261 093 Page 17
The 8 x 15 Ft model is shown.
7
6
5
3
2
.
See Section4-3B for installation
hardware torque values.
1
Extractor Side Bracket
2
Extractor Tray
3
Coupling Bracket
4
Left Extractor Housing Mounting
Bracket
7
5
Right Extractor Housing Mounting
Bracket
6
Angle Flange Adapter Duct
7
Extractor Top Cover
Use 1/4 x 3/4 in. screws and nuts to as-
semble extractor side bracket halves.
Use 5/16 x 3/4 in. screws to attach ex-
tractor tray to extractor side brackets.
Use 1/4 x 3/4 in. screws to attach coup-
ling bracket to extractor side brackets.
4
Use 1/4 x 3/4 in. screws to attach left and
right extractor housing mounting brack-
ets to extractor side brackets.
Use 3/8 x 1 in. screws, washers, and nuts
to attach angle flange adapter duct to ex-
tractor top covers.
Use 1/4 x 3/4 in. screws and nuts to at-
1
tach extractor top covers to extractor side
5
brackets.