C – Electrical requirements
WARNING:
All aspects of the installation must conform to the requirements of the standard North
American wiring rules, as well as your local electrical and building codes and regulations,
and any other applicable requirements and conditions of your local power supply
authority. A licensed electrician must perform the electrical work when installing this
appliance. The supply cable and fuse rating must be suitable for the appliance. The range
is supplied with a 40AMP corded plug.
240Volt 60Hz 40AMP (range with ceramic cooktop)
240Volt 60Hz 30AMP (range with gas cooktop)
Note:
To the electrician – please ensure sufficient supply cable is provided to allow the appliance to be
removed from the cavity should any servicing be necessary. This will also allow easy connection
of the supply.
Voltage supply connection, if unit not supplied with power cord
To connect the electrical supply:
1- This appliance must be installed individually on a separate and distinct final sub-circuit.
2- Ensure the supply cable and fuse rating are suitable for the appliance (see the electrical
loading).
3- Remove the cover plate by undoing the screw.
4- Fit a suitable entry bush to the conduit entry on the rear left of the appliance (with the rear
toward you) and feed the fixed wiring through.
5- Connect the wiring to the terminal block using the screw connections provided. Ensure
the wires are properly secured to prevent any high resistance electrical connection.
6- Replace the cover plate making certain that the supply wiring is clear of any metal work
and the screws.
7- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid hazard
When connected to a sub circuit, protected by a circuit breaker, it is recommended the circuit
breaker be the same as the total rating of the appliance.
To fully disconnect the power supply, it is necessary to have a proper mean in the fixed
wiring in accordance with the wiring rules. It must have full disconnection under
overvoltage category III conditions.
If you wish a direct connection to the line, it is necessary to use a double pole switch, with a
minimum opening between the contacts of 3mm. suitable for the purpose and in compliance with
local regulations (the green ground cable should not be interrupted by the switch).