Table 1
Fig.7
7/C
REGULATING THE MINIMUM OUTPUT OF THE COOKTOP BURNERS
Normal/valve taps:
Ignite the burners and turn the knob to the minimum position. Remove the knob and insert a small
flat-head screwdriver into the rod or through the holes on the side of the control panel, in
accordance with the type (fig. 8 A/B). Adjust the screw until the flame is lowered but stable, even
when rapid changes are made from the maximum to the minimum position with the burner cold. If
safety taps are fitted, let the burner run on minimum for a few minutes to ensure that the device
does not cut in. If it does, increase the minimum.
N.B. For liquid gas settings, the burner minimum must be set by fully tightening the tap
by-passes.
Fig.8
5