CONNECTION TO THE GAS SUPPLY: CURRENT INSTALLATION STANDARDS
The range should be connected according to local regulations, using
either a rigid or flexible connections.
a) For building in: Use a continuous flexible stainless steel pipe,
as per current installation standards, which can be extended
to a maximum of 2000mm.; the ends of the pipe must be fitted
with an ISO 228/1coupling and gasket or an ISO 7/1 threaded
coupling with mechanical gasket.
b) For free standing: A non-metallic flexible pipe can be used as
long as it complies with current standards and the following
installation instructions are observed: the pipe must be longer
than 400mm and shorter than 1500mm; it must not exceed
50°C at any point; it is not pulled or twisted; it cannot be
choked and the entire edges, sharp corners or other similar
hazards.
Before connecting the non-metallic flexible pipe, the brass
adapter and gasket supplied with the range and/or available from the reseller must be fitted to
the pipe/gas train on the back of the range. The regulator provided should be positioned
between the brass adapter and the non metallic flexible pipe.
c) A certified gas plumber must complete the installation and meet with local regulation
requirements for gas connections. Where the unit has an armour cable a certified electrician
must complete the electrical connection. The white, or neutral wire will not be used and must
be capped using a marrette.
WARNINGS:
In order to prevent tipping of the appliance, the safety chain must be attached to a
hook secured to the wall.
(PLEASE NOTE: The fixing hook is not provided as the type will depend on the
construction of the wall to which it will be drilled and fitted. The installer should provide
the fixing hook per customer request).
Washer inside brass adaptor
Brass Adaptor
Show the regulator....