H - Electrical Wiring Diagrams And Instructions - Porter & Charles SOPS76TM Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

H - Electrical wiring diagrams and instructions

WARNING:
All aspects of the installation must conform with the requirements of the standard North
American wiring rules, as well as your local electrical and building codes and regulations,
and any other applicable requirements or conditions of your local power supply authority.
A licensed electrician must perform the electrical work when installing this appliance. The
supply cable and fuse rating must be suitable for the appliance
240 Volt 60Hz 30AMP single/40AMP double service
208 Volt 60Hz 20AMP single/40 AMP double service
SEO76 Single Oven
Condominium Electrical Requirements: 208 Volt, 60hZ, 3460 Watt, 20 AMP
Residential Electrical Requirements: 240 Volt, 60hZ, 4580 Watt, 30 AMP
WARNING:
Porter&Charles
ovens are supplied with a 5" long electrical cable and must be hard wired to
the electrical supply.
ground. A licensed electrician must connect the armour cable and 3 wires into the
electrical connection box. The white, or Neutral wire is not used, and must be capped
using a marette.
To avoid power borne interference, this appliance must be installed individually on a separate and
distinct final sub-circuit.
Note:
To the electrician – please ensure sufficient supply cable is provided to allow the appliance to be
removed from the cavity should any servicing be necessary. This will also allow easy connection
of the supply.
Voltage supply connection
To connect the electrical supply:
1- Ensure the supply cable and fuse rating are suitable for the appliance (see the electrical
loading).
2- Remove the cover plate by undoing the screw.
3- Fit a suitable entry bush to the conduit entry on the rear left of the appliance (with the rear
toward you) and feed the fixed wiring through.
4- Connect the wiring to the terminal block using the screw connections provided. Ensure
the wires are properly secured to prevent any high resistance electrical connection.
5- Replace the cover plate making certain that the supply wiring is clear of any metal work
and the screws.
When connected to a sub circuit, protected by a circuit breaker, it is recommended the circuit
breaker be the same as the total rating of the appliance
Porter&Charles
ovens use Red and Black live wires and Green for
24

Publicité

Chapitres

Table des Matières
loading

Table des Matières