Connecting The Luminaire With Plug-In Connector; Operation; Switch-On And Switch-Off; Replacing The Lamp - Waldmann ACANEO Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connection
4.2
Connecting the luminaire
with plug-in connector
Designation
Cable type
Number of wires
Cable cross-sec-
tion (per wire)
Diameter of
sheathed cable
Sheath stripping
length
Wire stripping
length
Tab. 4: Required cable.
X Determine the socket assignment
according to the following tables.
E
D
No.
Assignment
A
PE
B
L
C
DALI / −
D
DALI / +
E
N
Tab. 5: Socket, view from behind; "DALI/CLO",
"DALI" , "1-10 V" .
Specification
Flexible cable
3 / 5
0.75 - 4 mm²
10 - 14 mm
PE: 30 mm
N, L, Dali: 25 mm
8 mm
A
C
No.
Assignment
A
N
B
L
C
PE
Tab. 6: Socket, view from behind; „EA" , „F" .
X Connect the cable to the socket.
X Connect the socket to the plug on the
luminaire.
5.

Operation

5.1

Switch-on and switch-off

NOTES:
B
The luminaire is not equipped with a
ƒ
C
switch of its own. The luminaire will
switch on when it is supplied with
power.
The preset minimum dimming value
ƒ
must not be modified.
6.

Replacing the lamp

NOTE: The lamp of this luminaire cannot be
replaced. When the lamp has reached the
end of its useful life, the entire luminaire
must be replaced.