Connection
4.
Connection
4.1
Connecting the luminaire to
the mains voltage (mains ver-
sion)
NOTE: This chapter applies only to lumi-
naires with the letter N in the model num-
ber, for example MQAL 24 N.
To connect the luminaires, connecting
cables are recommended, which can be
found in the Waldmann range of acces-
sories.
WARNING
Danger of death due to electric shock.
X The connection must be made by a
trained skilled electrician only.
NOTICE
Material damage caused by wrong
mains voltage.
Damage or destruction of the luminaire.
X Compare the mains voltage with the
nominal voltage and the frequency
specified on the rating plate and make
sure that they are identical.
X Observe the pin assignment and
the socket assignment.
X Use connecting cable with strands
which have a conductor cross-sec-
tion of at least 1.0 mm². For lumi-
naires with through-wiring, use a
connecting cable with a cross-sec-
tion of at least 1.5 mm².
3
4
No. Designation
1
Not used
2
External conductor/phase (L)
3
Neutral conductor (N)
4
Protective earth conductor (PE)
Tab. 3: MQAL xx N pin assignment.
X Connect a suitable socket with the
S-coded plug.
ENG
2
1
21