Connection
4.
Connection
4.1
Connecting the luminaire to
the mains voltage (mains ver-
sion)
NOTE:This chapter applies only to lumi-
naires with the letter N in the model
number,forexampleMQAL24N.
To connect the luminaires, connecting
cables are recommended, which can be
found in theWaldmann range of acces-
sories.
WARNING
Danger of death due to electric shock.
X Theconnectionmustbemadebya
trainedskilledelectricianonly.
NOTICE
Material damage caused by wrong
mains voltage.
Damageordestructionoftheluminaire.
X Comparethemainsvoltagewiththe
nominal voltage and the frequency
specifiedontheratingplateandmake
surethattheyareidentical.
X Observethepinassignmentand
thesocketassignment.
X Useconnectingcablewithstrands
whichhaveaconductorcross-sec-
tionofatleast1.5mm².
NOTICE
Material damage caused by unsuita-
ble connecting cable and socket.
Degreeofprotectionoftheluminaireis
not guaranteed. Penetrating humidity
damagestheluminaire.
X Useconnectingcableandsocket
whichguaranteethedegreeofpro-
tectionoftheluminaire.
3
4
No. Designation
1
Notused
2
Externalconductor/phase(L)
3
Neutralconductor(N)
4
Protectiveearthconductor(PE)
Tab.3:MQALxxN pinassignment.
X Connect a suitable socket with the
S-codedplug.
ENG
2
1
21