5.6 CONNECTING THE POWER CABLE

To access the terminal board, just remove the ap-
pliance's rear sidepanel. Loosen the cable gripper
and allow the cable to pass through it. Arrange the
conductors so that the earth conductor is the last
to detach from its terminal if the cable goes into
a state of faulty traction. Connect the phase con-
ductors to the terminals marked "L1" and "L2",
connecting the neutral conductor to the terminal
marked "N" and the earth conductor to the ter-
minal marked with the symbol
EN
following lay-out:
230V
N
L
5.7 SAFETY THERMAL BREAKER
The appliance has a manually reset safety thermal
breaker. It protects against excessive dangerous
over-temperatures which could be accidentally
8
Fig. 1
according to the
400V / 2N
L
N
L
2
1
(this electrical connection lay-out is located near
the power supply terminal board). Tighten the ca-
ble gripper and re-fi t the rear side-panel of the
appliance.
The appliance must be connected to an equipoten-
tial system whose effi ciency must fi rst be checked
according to current legal regulations.
This connection must be made between different ap-
pliances by using the appropriate terminal marked
with the symbol
must have a minimum diameter of 2,5 mm². The
equipotential terminal is at the rear of the appliance.
L
2
1
generated inside the appliance. This device is lo-
cated on the back of the oven.
Fig. 2
. The equipotential conductor