• The warehouse inside temperature must not be lower than -9°C; otherwise, the
thermostat (regulation and safety thermostat) control devices of the machine will
be damaged. Failure to observe this prohibition invalidates any responsibility of
the manufacturer of the machine.
• The appliance is intended for professional use and must be utilised by qualifi ed
personnel trained to use it.
• Any modifi cation which may be necessary on the electrical system to enable in-
stallation of the appliance, must be carried out solely by competent personnel.
• It is dangerous to modify or attempt to modify the characteristics of this appliance.
• Never clean the appliance with direct water jets, because, if any water enters, it
could limit the machine's safety.
• Before doing any maintenance or cleaning jobs, disconnect the appliance from
the electrical mains and allow it to cool.
• When the tilting door is wide open, do not put anything on the surface, be-
cause the door hinges could be irreparably damaged.
• Do not attempt to carry out the periodic controls or any repairs by yourself. Con-
tact the nearest Service Centre and use only original spare parts.
N.B.: Improper or incorrect use and failure to observe the installation instructions
shall release the manufacture from all responsibility. In this connection, the direc-
tives in the "POSITIONING" paragraph must be strictly observed.
4. TECHNICAL SPECIFICATIONS
Dimensions of appliance LxDxH (mm)
Weight (Kg)
Convection heating element (kW)
Max. absorbed power (kW)
Power supply voltage (V)
Power cable diameter
Type of cable
Connecting electric cable
Class
Degree of protection against humidity
Water pressure (kPa)
The noise level of the appliance in operation is below 70 dB (A).
The II technical data II plate is positioned on the rear panel of the appliance.
790x750x635
58
3,0
6,4
400V ~50/60Hz
4x2,5 mm2
H07RN-F
Type Y
I
IPX3
100-200
EN
5