Elixo 500 3S io
Code
description
p19
Closing speed
p20
Opening speed
p21
Closing slowdown zone 1: shortest slowdown zone
p22
Opening slowdown
zone
p25
Closing torque limitation 1: minimum torque
p26
Opening torque
limitation
p27
Closing slowdown
torque limitation
p28
Opening slowdown
torque limitation
p33
Obstacle detection
sensitivity
p37
Wired control inputs
p40
Coupling speed when
closing
p41
Coupling speed when
opening
17
values (bold = default)
1: slowest speed
at
10: fastest speed
default value: 5
1: slowest speed
at
10: fastest speed
default value: 5
at
5: longest slowdown zone
default value: 1
1: shortest slowdown zone
at
5: longest slowdown zone
default value: 1
at
10: maximum torque
adjusted at the end of self-learning
1: minimum torque
at
10: maximum torque
adjusted at the end of self-learning
1: minimum torque
at
10: maximum torque
adjusted at the end of self-learning
1: minimum torque
at
10: maximum torque
adjusted at the end of self-learning
0: very low sensitivity
1: slightly sensitive
2: standard
3: very sensitive
0: complete cycle mode -
pedestrian cycle
1: opening mode - closing
1: slowest speed
at
4: fastest speed
default value: 2
1: slowest speed
at
4: fastest speed
default value: 2
Setting
Comments
completed
If this parameter is modified, the installer must check that the limitation of forces
complies with appendix A of the standard EN12 453 or install a safety edge.
If this parameter is modified, the installer must check that the limitation of forces
complies with appendix A of the standard EN12 453 or install a safety edge.If the
torque is too low, there may be erratic obstacle detection.
If the torque is too high, the installation may not comply with the standard.
If this parameter is modified, the installer must check that the limitation of forces
complies with appendix A of the standard EN12 453 or install a safety edge.
0: terminal 9 input = pedestrian cycle, terminal 11 input = complete cycle
1: terminal 9 input = opening only, terminal 11 input = closing only
If this parameter is modified, the installer must check that the limitation of forces
complies with appendix A of the standard EN12 453 or install a safety edge.
Copyright © 2015 Somfy SAS. All rights reserved.