Electrical Pre-Equipment; Safety Instructions Relating To Installation - SOMFY ELIXO 500 3S io Manuel D'installation

Masquer les pouces Voir aussi pour ELIXO 500 3S io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Elixo 500 3S io

Electrical pre-equipment

The installation of the power supply must comply with the standards in force in the country in which the motorisation is
installed, and must be carried out by qualified personnel.
The electric line must be exclusively reserved for the motorisation and equipped with protection, comprising:
- a 10 A fuse or breaker,
- a differential type device (30 mA).
An all-pole supply cut-off device must be provided.
It is recommended that you fit a lightning conductor (maximum residual voltage 2 kV).
> cable feed
Underground cables must be equipped with a protective sheath with a sufficient diameter to contain the motor cable and
the accessories cables.
For overground cables, use a cable grommet that will withstand the weight of vehicles (ref. 2400484).

Safety instructions relating to installation

Do not connect the motorisation to a power source (mains, battery or solar) before installation is complete.
Ensure that any danger zones (crushing, cutting, trapping) between the driven part and the surrounding fixed elements
caused by the opening movement of the driven part are avoided or indicated on the installation (see the section on risk
prevention).
Modifying one of the elements provided in this kit or using an additional element not recommended in this manual is
strictly prohibited.
Monitor the gate as it moves and keep people away from it until installation is complete.
Do not use adhesive to secure the motorisation.
Manual back release device: see paragraph concerning this device in the user manual for the motorisation.
Manual unlocking may result in uncontrolled movement of the gate.
Install any fixed control device at a height of at least 1.5 m and within sight of the gate, but away from moving parts.
After installation, ensure that:
- the mechanism is correctly adjusted
- the manual back release device is operating correctly
- the motorisation changes direction when the gate encounters an object 50 mm high positioned halfway up the leaf.
> Safety devices
For operation in automatic mode or remote control, photoelectric cells must be installed.
For operation in automatic mode, or if the gate faces a public road, an orange light type signalling device may be required
to comply with the regulations in the country in which the motorisation is installed.
> clothing precautions
Take off any jewellery (bracelet, chain, etc.) during installation.
For manoeuvring, drilling and welding operations, wear appropriate protection (special glasses, gloves, ear protection,
etc.).
3
DANGER
DANGER
WARNING
WARNING
WARNING
Attention
WARNING
Copyright © 2015 Somfy SAS. All rights reserved.

Publicité

Table des Matières
loading

Table des Matières