Code
description
values (bold = default)
p03
Pedestrian cycle
0: identical to complete cycle
operating mode
operating mode
1: without automatic closing
2: with automatic closing
p04
Short automatic closing
0 to 30 ( value x 10 s = time delay
time delay in pedestrian
cycle
2: 20 s
p05
Long automatic closing
0 to 99 ( value x 5 min = time delay
time delay in pedestrian
0: 0
cycle
p06
Pedestrian opening
1 to 9
1: 80 cm
amplitude
p07
Cell safety input
0: inactive
1: active
2: active with autotest via test
output
3: active with autotest via power
supply switching
4: bus cells
p08
Safety edge safety
0: inactive
input
1: active
2: active with auto-test
p09
Programmable safety
0: inactive
input
1: active
2: active with autotest via test
output
3: active with autotest via power
supply switching
p10
Programmable safety
0: active closing
input - function
1: active opening
2: active closing + ADMAP
3: all movement disabled
p11
Programmable safety
0: stop
input - action
1: stop + partial reversal
2: stop + complete reversal
p12
0: no warning
Orange warning light
1: with 2 s warning prior to
movement
p13
Area lighting output
0: inactive
1: controlled operation
2: automatic + controlled
operation
p14
Area lighting time delay 0 to 60 ( value x 10 s = time delay
6: 60 s
p15
Auxiliary output
0: inactive
1: automatic: gate open indicator
light
2: automatic: timed bistable
3: automatic: one-touch
4: controlled: bistable (ON-OFF)
5: controlled: one-touch
6: controlled: timed bistable
p16
Auxiliary output time
0 to 60 ( value x 10 s = time delay
delay
6: 60 s
Copyright © 2015 Somfy SAS. All rights reserved.
Setting
completed
value)
value)
value)
value)
Comments
Pedestrian cycle operating mode is identical to the complete
cycle operating mode selected.
The pedestrian cycle
If P01=1, the gate does not close automatically following a
operating mode
pedestrian opening command.
parameters can only
be set if P01 = 0 to 2
Operation in automatic closing mode is only authorised if the
The P03 = 2
photoelectric cells are fitted. i.e. P07=1 to 4.
operating mode is
Irrespective of the value of P01, the gate does not close
not compatible with
automatically following a pedestrian opening command.
remote control using a
The automatic closing time delay can be programmed in
TaHoma unit.
parameter "p04" (short time delay) or parameter "p05" (long
time delay).
If value 0 is selected, the gate immediately closes automatically.
Value 0 must be selected if the short automatic closing time delay in pedestrian cycle
is active.
1: minimum pedestrian opening
...
9: maximum pedestrian opening (approximately 80% of the gate's total travel)
0: the safety input is not taken into account.
1: safety device without autotest; it is essential to check that it is operating correctly
every 6 months.
2: the autotest is run on the device for each operating cycle via the test output, reflex
photocell application with autotest.
3: the autotest is run on the device for each operating cycle via power supply switching
of the cell power supply output (terminals 21 and 22).
4: bus cells application.
0: the safety input is not taken into account.
1: safety device without auto-test.
2: the autotest is run on the device for each operating cycle via the test output.
0: the safety input is not taken into account.
1: safety device without auto-test.
2: the autotest is run on the device for each operating cycle via the test output.
3: the autotest is run on the device for each operating cycle via power supply switching
of the cell power supply output (terminals 21 and 22).
0: the programmable safety input is only active when closing.
1: the programmable safety input is only active when opening.
2: the programmable safety input is only active when closing and, when activated, the
gate cannot be opened.
3: emergency stop application; if the programmable safety input is activated, the gate
cannot be moved.
0: emergency stop application, compulsory if p10=3
disabled if a safety edge is connected to the programmable safety input.
1: recommended for a safety edge application.
2: recommended for a cell application.
If the gate opens onto a public path, the "with warning" configuration must be selected:
P12=1.
0: the area lighting output is not taken into account.
1: the area lighting is remotely controlled.
2: the area lighting is remotely controlled when the gate is stationary
+ the area lighting comes on automatically when the gate is moving, and remains
on when it stops moving for the duration of the time delay programmed in parameter
"p14".
p13=2 is compulsory for operation in automatic mode.
If value 0 is selected, the area lighting goes out as soon as the gate stops moving.
0: the auxiliary output is not taken into account.
1: the gate indicator light is off when the gate is closed, flashing when the gate is
moving and on when the gate is open.
2: output activated when movement starts, during movement then deactivated at the
end of the time delay programmed in parameter "p16".
3: one-touch at contact when movement starts.
4: operation changes as follows each time the memorised button on the radio control
point is pressed: ON, OFF, ON, OFF...
5: one-touch at contact by pressing the memorised button on the radio control point.
6: output activated by pressing the memorised button on the radio control point then
deactivated at the end of the time delay programmed in parameter "p16".
The auxiliary output time delay is only active if the value selected for P15 is 2 or 6.
Elixo 500 3S io
16

Publicité

Table des Matières
loading

Table des Matières