advanCEd paraMEtEr SEttIng

navigating the parameter list

press ...
to...
Access and exit the parameter setting menu
Navigate the parameters and codes list:
. short press = normal scrolling through individual parameters
. press and hold = rapid scrolling through parameters
Confirm:
. the parameter selection
. the parameter value
Increase/decrease the value of a parameter
. short press = normal scrolling through individual parameters
. press and hold = rapid scrolling through parameters

parameter value display

If the display is fixed, the displayed value is the value selected for this parameter.
If the display is flashing, the displayed value is the value selectable for this parameter.

Meaning of different parameters

Code
description
p01
Complete cycle
operating mode
p02
Complete operating
mode automatic timed
closing
15
values (bold = default)
0: sequential
1: sequential + timed close
2: semiautomatic
3: automatic
4: automatic + cell blocking
5: deadman's control (wire)
0 to 30 ( value x 10 s = time delay
value)
2: 20 s
Setting
Comments
completed
Each press on the remote control causes the motor to move (initial position: gate
closed) as per the following cycle: open, stop, close, stop, open, etc.
Operation in
In sequential mode with automatic timed close:
automatic closing
- the gate closes automatically after the time delay programmed
mode is only
in parameter "p02",
authorised if the
- pressing a button on the remote control interrupts the
photoelectric cells
movement taking place and the timed close (the gate remains
are fitted.
open).
i.e. P07=1 to 4.
In semiautomatic mode:
- pressing a button on the remote control during opening has no effect,
- pressing a button on the remote control during closing causes it to reopen.
In automatic closure mode:
- the gate closes automatically after the time delay programmed
in parameter "p02",
- pressing a button on the remote control during opening has
no effect,
Operation in
- pressing a button on the remote control during closing causes
automatic closing
it to reopen,
mode is only
- pressing a button on the remote control during the closing time
authorised if the
delay restarts the time delay (the gate will close when the new
photoelectric cells
time delay has elapsed).
are fitted.
If there is an obstacle in the cells' detection zone, the gate will
i.e. P07=1 to 4.
not close. It will close once the obstacle is removed.
These operating
modes are not
After the gate is opened, movement in front of the cells (safe
compatible with
closure) will close the gate after a short time delay (fixed at 2
remote control using
seconds).
a TaHoma unit
If there is no movement in front of the cells, the gate will close
automatically after the timed close programmed in parameter
"p02".
If there is an obstacle in the cells' detection zone, the gate will
not close. It will close once the obstacle is removed.
In wired deadman mode*
- the gate can only be controlled by continuous action on a wired control,
- the radio controls are inactive.
If value 0 is selected, the gate immediately closes automatically.
Press SET to exit the parameter setting menu.