Never refuel the generator when running. After being
operated, let the generator cool down for at least 5
minutes before refuelling.
Do not touch the hot parts of the generator.
Do not store fuel near the generator.
The suppressor and air filter act as a flame catcher
when sufficient combustion is provided. Therefore,
make sure these parts are installed properly and in a
perfect technical state.
Use as designated
The generator has solely been designed to drive electric
devices with the maximum output being within the
generator output. The higher level of the starting current of
induction appliances must be considered.
The manufacturer cannot be held liable if provisions of the
generally applicable regulations and these Operating
Instructions are not adhered to.
Installation and first activation
Oil filling (see pic. 6)
The generator is always supplied without oil.
Please check the average ambient temperature
and add one of the given oil types to the
generator:
 S AE 10 or 10W30; 10W40
< 0°
0°-25°
SAE 20 or 10W30; 10W40
25°-35°
SAE 30 or 10W30; 10W40
35° >
SAE 40 or 10W30; 10W40
Important: The generator is fitted with a lack of
oil protection. The appliance cannot
be started when there is a low oil
level (the oil level indicator lights up
at attempted start).
The oil level must necessarily be checked
before using the generator.
Refuelling
Never refuel the appliance when running. After
being operated, let the appliance cool down for
at least 5 minutes and then you can refuel.
Fuel: unleaded petrol.
Never smoke near the appliance or
fuel. Never refuel near sparks, flames or open
fire.
Important: Remove all cables.
Remove the lid from the filling hole.
Add carefully fuel to the filling hole.
Never fill the tank higher than the upper
side of the fuel filter.
Apply the lid to the filling hole again.
Operation
Using the generator, "Starting" (pic. 2)
Open the fuel tap
"ON" switch
Put the choke to the starting position (see
the Air filter).
12
Pull slowly the starting cable until you can
feel resistance – then pull strongly to start
the engine.
After the engine has warmed up, put the
choke back to the starting position and wait
until the signal indicator lights up.
Connect the appliance.
The overload protection is activated if the output is
overloaded. The signal indicator keeps lighting.
The generator is automatically switched off in case of
short circuit.
Switching the generator off (pic. 3)
Make sure that NO appliance is connected.
Turn the ON/OFF switch to the "OFF"
position.
Turn the fuel tap to the "OFF" position.
See the General safety instructions and Safety
instructions for the first activation.
Use the appliance only after you have carefully read
the Operating Instructions.
Follow all safety instructions specified in the
Operating Instructions.
Behave responsibly to other persons.
Signs on Unit
Product Safety:
Product compliance with
respective EU standards
Bans:
General ban combined with
another pictograph
Do not use the unit in rain
Warnung:
Warning/Caution
Commands:
General prohibition sign
Use ear protectors
No smoking, no fire,
unprotected light
Do not use in buildings.
Danger from hot surfaces
Read operation manual