3. Connection of the optional pedal

※ When using the optional pedal, refer to " 2-(4) Setting the pedal specifications " described in the item of
"* . HOW TO USE THE MEMORY SWITCH ".
(1) Connection of the 2-step pedal
J26
J18
(2) Connection of the PK-57
J18
1
J71 P34
(3) Connection of the 2-step PK pedal
Ground cable
J26
J18
1
1) Remove the standard pedal cord from J18
connector on the MAIN circuit board.
2) Enter the 2-step pedal cord into the control box
and connect it with J26 connector on the MAIN
circuit board.
2-step pedal : Part No. M85205800A0
* Memory switch No. 10-1
1) Remove the standard pedal cord from J18
connector on the MAIN circuit board, and connect
PK-57 change cable 1.
2) Connect the cord of PK-57 with J71 of PK-57
1
change cable 1 at the rear face of the control box.
Then, clamp two places with adhesive clamp 2.
Also, tighten with a screw the PK-57 ground cable
as illustrated in the figure.
* Memory switch No. 10-2
2
Ground cable
1) Remove the standard pedal cord from J18
connector on the MAIN circuit board.
2) Enter the 2-step PK pedal cord into the control box,
connect it with the 2-step pedal connecting cord
asm.1, and connect it with J26 connector on the
MAIN circuit board.
Tighten with a screw the ground cable as illustrated
in the figure.
2-step PK pedal : Part No. M85905130AA
2-step pedal
connecting cord asm. : Part No. M90315800A0
* Memory switch No. 10-1
PK-57
: Part No. GPK570010B0
PK-57 change cable : Part No. M90135900A0
Adhesive clamp
: Part No. E96076030000
(2 pcs.)