(4) Connection of the 3-step pedal
J26
J18
(5) Connection of the 3-step PK pedal
J26
J18
1
Either J18 or J26 of MAIN circuit board can be used for the pedal.
Be careful when the optional pedal is used since the machine may fail to work if
both connectors are simultaneously connected.
56
1) Remove the standard pedal cord from J18
connector on the MAIN circuit board.
2) Insert the 3-step pedal cord into the control box
and connect it to J26 connector of the MAIN circuit
board.
3-step pedal : Part No. M85215800A0
* Memory switch Nos. 10-3 to -5
1) Remove the standard pedal cord from J18
connector on the MAIN circuit board.
2) Enter the 3-step PK pedal cord into the control box,
connect it with change cable asm. 1, and connect
it with J26 connector on the MAIN circuit board.
(Refer to the table below for the connection.)
3-step PK pedal : Part No. GPK470010AB
Change cable : Part No. M90255800A0
* Memory switch Nos. 10-3 to 5
PK-47
Relay cord
P1
P101
P2
P102
P3
P103
-
P104
P4
P105
Signal name
Feeding frame 1
Feeding frame 2
Feeding frame 3
Not used
Start