PFAFF silberblau BETA SILVERLINE Mode D'emploi page 27

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electric wire rope winch >BETA< SILVERLINE
English
Brake-wear monitoring
For wear monitoring of the brake, regularly check the release path and if necessary adjust it.
If the release path cannot be adjust any more replace the brake disk.
Works on the brake may only be executed by authorised and competent personnel.
type of brake
∆ n=100 min -1
M K [Nm]
± 0,05mm
P 5
L 4
L 8
L 16
L 32
Special adjusting are to be demanded!
The electric wire rope winches are classified according to different drive groups, DIN 15020, FEM 9.511, ISO4301/1 (see tech.
data, page 17)
Those drive groups refer to the rope drive and all mechanical parts of the winch.
It determines the period of time of safe operation depending on load collective.
running
time
medium running time per day in hour, related to one
category
Term
no.
load
exceptionally max. load, continuously very small loads
light
1
collec-
often max. load, but continuously small loads
me-
2
tive
dium
frequent max. load, continuously average loads
heavy
3
very
4
heavy
Calculated operating times acc. to FEM 9.755
DIN 15020/1 FEM 9.511
ISO 4308/1; SO 4301/1
Load collective
line
factor of the load spectrum
light 1 - L1
1
k = 0,5 (km 1 = 0,125 = 0,5
medium 2 - L2
2
0,5 < k < 0,63 (km 1 = 0,25 = 0,63
heavy 3 - L3
3
0,63 < k < 0,8 (km 1 = 0,5 = 0,8
very heavy 4- L4
4
0,8 < k < 1,0 (km 1 = 1 = 1,0
*) not included in FEM 9.511
Apart from drive groups, the rope has to be checked and serviced regularly acc.g to DIN15020, if
necessary, replace.
By comparing those data with the actual operating conditions and times the consumed part of the calculated
operating time can be determined
The consumed part of the calculated operation has to be recorded by the operator (i.e. writing,
counting, measuring)
After expire of the calculated working life the winch has to be given a thorough examination 1)
1) only by manufacturer or competent personnel authorised by manufacturer
technische Änderungen vorbehalten
release path
S Lü [mm]
nominal
max.
0,2
0,5
0,2
0,5
0,2
0,5
0,2
0,5
0,3
0,7
Explanation to drive groups FEM 9.511 for rope drives
Symbol
year
Explanation
k < 0,50
0,50 < k < 0,63
0,63 < k < 0,80
continuously max. load and adjacent loads
0,80 < k < 1,00
Drive group
1E m *
(400) *
3
)
(200) *
3
)
(100) *
3
)
(50) *
3
)
design changes under reserve
gage
S
release path
V 006
V 012 V 025
V 05
≤ 0,12 ≤ 0,25 ≤ 0,5
≤ 1
Drive group acc. to FEM9.511, DIN15020, ISO4301
1 E m* 1 E m* 1 D m 1 C m 1 B m 1 A m
1 E m* 1 D m 1 C m 1 B m 1 A m
1 D m 1 C m 1 B m 1 A m
1 C m 1 B m 1 A m
2 m
1D m
1C m
1B m
1A m
M 1
M 2
M 3
calculated operation time D (h)
800
1600
3200
6300
400
800
1600
3200
200
400
800
1600
100
200
400
changements techniques sous réserve
04.01.401
Type key
V 1
V 2
V 3
≤ 2
≤ 4
≤ 8
2 m
2 m
3 m
2 m
3 m
4 m
3 m
4 m
5 m
2 m
3 m
4 m
M 4
M 5
M 6
M 7
12500 25000 50000 100000
6300
12500 25000 50000
3200
6300
12500 25000
800
1600
3200
6300
V 4
V 5
≤ 16
≥ 16
3 m
4 m
4 m
5 m
5 m
5 m
M 8
12500
Seite / page 27