Technical Information

TwisTorr 704 FS On Board Controller Installation

TwisTorr 704 FS On Board Controller Installation

The controller can be mounted in two positions:
To install the controller execute the following procedures.

Bottom Mounting

See the following figure 43.
1
2
3
4
5
6
314/334
bottom mounting (as per the complete system);
side mounting.
Turn the pump upside-down;
Fix the plastic ring to the pump by means of the three socket
head screws M6, with the pump cable toward the pump body;
Fix the controller to the plastic ring by means of the three socket
head screws M5;
Turn the pump again;
Plug the main cable and connect the pump cable to the pump;
Connect the mating connector with the jumper on the interlock
signal to start the pump.