Télécharger Imprimer la page

Agilent Technologies TwisTorr 704FS Mode D'emploi page 316

Publicité

17
Technical Information
TwisTorr 704 FS On Board Controller Installation
3
4
5
6
7
8
9
Figure 44
316/334
Place the bracket on the pump bottom (the hole on the bracket
has the same diameter as the pump bottom flange);
Screw a little bit the three screws M6 in the holes on the pump
bottom;
Rotate the bracket until the controller is on the chosen position;
Tighten the screws properly;
Turn the pump again;
Plug the main cable and connect the pump cable to the pump;
Connect the mating connector with the jumper on the interlock
signal to start the pump.
TwisTorr 704 FS User Manual / 87-901-051-01 (A)