ELECTRICAL FEEDER CABLE CONNECTION
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
To connect the supply cable:
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A" (fig.
•
11.1).
Unscrew the screw "D" and open completely the cable clamp "E" (figs. 11.2 - 11.3 - 11.4).
•
Position the U bolts "F" onto terminal board "G" (figs. 11.2 - 11.3 - 11.4) according to the
•
diagrams in fig. 11.5.
•
Connect the phase, neutral and earth wires to terminal board "G" according to the
diagrams in fig. 11.3.
•
Strain the feeder cable and block it with cable clamp "E" (by screwing screw "D").
•
Close the terminal block cover (check the two hooks "A" are correctly hooked).
NOTE: The earth conductor must be left about 3 cm longer than the others.
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws fixing
the cover plate behind the terminal block.
FEEDER CABLE SPECIFICATIONS
Type "H05RR-F" or "H05VV-F"
220-240 V ac
380-415 V 3N ac
380-415 V 2N ac
(**) Connection with wall box connection.