Connect the appliance to the mains electricity supply
as follows.
1 – If not already present, install an automatic circuit-
breaker (B), close to the appliance, with the following
characteristics.
– Thermal breaker device (to adjust see table on
page 4).
– Differential breaker set at 30 mA
– Class B or C (IEC 898)
2 – Undo the screws and remove the side panel (A).
3 – Connect the automatic circuit-breaker (B) to t he
appliance's terminal board (C) and to the electrical
mains supply, in accordance with the electrical sys-
tem diagram provided at the back of the manual and
using a cable with the following characteristics.
– Weight:
than H05RN-F type (designation 245 IEC
57)
– Temperature of use:
70°C.
Important
When connecting, take care to connect the neu-
tral and earth lines.
4 – Replace the panel and retighten the screws when the operation is complete.
CONVERSION OF ELECTRICITY SUPPLY (FX 82)
To carry out this operation, proceed as follows.
1 – Disconnect the mains electricity supply.
2 – Undo the screws to remove the side panel (A).
3 – Fit the jumper (B) to make the electrical connection
of the terminals (C-D) (see attached wiring diagrams).
4 – Remove the carter (G) and change the connec-
tions to the heating element terminals (H) as shown
in figure.
400 V
H
English
230 V
H
- 57 -
B
C
B
C
D
A
IDM-39617701600.tif
A
IDM-39617701700.tif
G
IDM-39617701900.tif
Use and installation manual
IT
GB
DE
FR
ES