REPLACING THE TOP BURNER NOZZLE (Ø130 - 10 KW)
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Unscrew the nozzle (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Replace the control panel (B) and the knobs (A)
on completion of the operation.
REPLACING THE TOP BURNER PILOT LIGHT NOZZLE
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panel (B).
4 - Remove the pipe (D).
5 - Remove the nozzle (E) and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
6 - Replace the pipe (D), the control panel (B) and
the control knobs (A).
DECOMMISSIONING THE APPLIANCE
Important
This operation must be carried out by
skilled operatives in compliance with the le-
gal requirements with regard to safety at
work. Never dump non-biodegradable ma-
terials, lubricating oils and non-metallic
C
A C
B
C
A C
B
components (rubber, PVC, resins, etc.) in
the environment. Dispose of them in ac-
cordance with the relevant legal require-
ments.
- 25 -
D
8
IDM-39616601700.tif
D
E
10
IDM-39616601800.tif
English
IT
GB
DE
FR
ES