Introduction

Dear Customer:
Thank you very much for purchasing our product. We are confident
that it will meet your expectations.
The HST 300 GeoTherm + 2.0 Welding Unit is designed exclusively for
welding plastic pipe fittings according to the electrofusion process,
with diameters 20 - 75 mm, as used in particular in geothermal system
pipeline construction. It represents the next generation of the tried
and tested HST 300 series, featuring a broader range of functions.
The product was manufactured and checked according to state-of-
the-art technology and widely recognized safety regulations and is
equipped with the appropriate safety features.
Before shipment, it was checked for operation reliability and safety.
In the event of errors of handling or misuse, however, the following
may be exposed to hazards:
• the operator's health,
• the product and other hardware of the operator,
• the efficient work of the product.
All persons involved in the installation, operation, maintenance, and
service of the product have to
• be properly qualified,
• operate the product only when observed,
• read carefully and conform to the User's Manual before working
with the product.
Thank you.
2

Safety Messages

2.1

Using the Correct Connection Terminal

Use the appropriate connection terminal that is compatible with the
fitting type used. Be sure the contact is firmly established and do not
use connection terminals or terminal adapters that are burnt or not
designed for the intended use.
2.2

Improper Use of the Welding and Power Supply Cables

Do not carry the product by its cables and do not pull the power cord
to unplug the unit from the socket. Protect the cables against heat,
oil, and cutting edges.
2.3

Securing the Fitting and the Joint

Use positioner clamps or a vice to secure the fitting and the joint
to be made before welding. The fitting manufacturer's installation
instructions, local and national regulations have to be respected in
all cases.
A welding process must never be repeated with the same fitting, since
this may cause parts under power to be accessible to the touch.
Version July 2013