Installation; Sauna Heater Installation - Tylo CURVE Notice D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
6
Positioning the heater - recess installation
Position the heater at a safe distance from the fl oor, side walls
and interior fi ttings (see Figure 3, Page 6).
1
1
Figure 3: Positioning the heater - recess installation
1.
Minimum distance from side wall: 200 mm
2.
Max. 1000 mm
3.
Minimum distance from ceiling: 1030 mm
4.
Minimum distance from interior fi ttings: 100 mm
5.
Minimum ceiling height: 1900 mm
6.
Minimum distance: 20 mm
7.
Minimum distance from interior fi ttings: 30 mm
8.
Distance from fl oor: 270 mm
Positioning the inlet vent
Install the inlet vent straight through the wall under the centreline
of the heater. Vent size for a family sauna approx. 125 cm².
The air circulation from the door must concord with the hot air
circulation from the heater.
1
3
Figure 4: Positioning the inlet and outlet vents
1.
Inlet vent position.
2.
Outlet vent position through the sauna wall.
3.
Outlet vent position through the cavity.
4.
Outlet vent position via duct.
3
4
2
5
7
6
8
2
4
Positioning the outlet vent
DANGER! The outlet vent must not lead outdoors.
This could cause the ventilation direction to be
reversed, which may negatively affect the heater
temperature cut-out.
DANGER! Any gap above the sauna ceiling
should not be sealed without leaving at least one
vent hole on the same wall as the sauna door.
Position the outlet vent:
at the maximum possible distance from the inlet vent, e.g.
diagonally (see Figure 4, Page 6)
high on the wall or in the ceiling (see Figure 4, Page 6).
so that it vents into the space the door and inlet vent open
into.
The outlet vent must have the same area as the inlet vent.
Ensure that the outlet vent is open.
Mechanical ventilation is not recommended due to the risk of poor
air exchange, which can negatively affect the heater temperature
cut-out.

INSTALLATION

Sauna heater installation

It is easiest to prepare for installation with the heater lying down.
To install the heater:
1.
Lay the heater down front upwards.
2.
Slacken the screws and open the cover (see Figure 5, Page
6).
Figure 5: Opening/closing the cover
WARNING! Always check that the heater is con-
nected to the correct main/phase voltage.
Connect the heater using standard wiring (Fk or EKK) approved
for fi xed installation.
Any single wires (Fk) must be protected in electrical conduits
(VP) to the heater.
3.
Connect the electrical cable (1) to terminal (2) (see Figure 6,
Page 7) according to wiring diagram (see The section called
Connection/wiring diagram, Page 8).

Publicité

Table des Matières
loading