07 ATEX 2063 X
DANGER!
Risk of short-circuit!
Damaged connection cables may cause a short-circuit.
• The connection cables for the coil must be laid permanently and
protected against damage.
Danger of burns/danger of fire during long-term operation!
The solenoid coil may become very hot during long-term operation.
• Take hold of a device which has been running for a prolonged
period with protective gloves only.
WARNING!
Danger – high pressure!
There is a serious risk of injury when reaching into the system.
• Only skilled and instructed personnel may work on the system
with suitable tools.
• Before disconnecting lines and valves, switch off the pressure
and bleed the lines.
• Observe applicable accident prevention and safety regulations
for pressurised devices!
• After an interruption in the power supply or fluid supply, ensure
that the process is restarted in a defined or controlled manner!
Installation
7.2. Installation
The solenoid valve with integrated coil AC19 can be ins-
talled in any location. Preferably with top-mounted drive.
Prior to installation:
→
Clean any dirt off the pipelines and flange connections.
Installation:
WARNING!
Risk of injury from leaking connections
Danger of explosion!
There is a danger of explosion in fuel pumps if oxygen or air pene-
trates the medium through leaking connections.
Risk of injury from escaping medium!
Medium which escapes through leaking connections may result in
injuries (e.g. burns or chemical burns).
• Carefully seal the connection lines.
→
Seal pipeline connections with PTFE tape. The tape must not be
dropped into the pipelines.
→
Screw in pipelines.
Important for function of the device!
Note the direction of flow.
→
Check valve for leakage.
english