6.4.1.
Electrical Data
Note the electrical data as specified on the rating plate.
12
english
07 ATEX 2063 X
Installation
7.
INSTALLATION
7.1. Safety Instructions
DANGER!
Danger of explosion!
Following installation, solenoid coil and valve body form a closed
system. If used in the EX area, there is a danger of explosion if the
system is opened during operation!
• The system must not be disassembled during operation.
Danger of explosion caused by electrostatic charge!
If there is a sudden discharge from electrostatically charged devices
or persons, there is a danger of explosion in the EX area.
• Take appropriate measures to prevent electrostatic charges in the
EX area.
• Clean the device surface of the solenoid valve by gently wiping
it with a damp cloth
Risk of electric shock!
There is a serious risk of injury when reaching into the equipment.
• Only trained electrical engineers may work on the electrical
system.
• Before starting work, always switch off the power supply and
safeguard to prevent re-activation!
• Observe applicable accident prevention and safety regulations
for electrical equipment!