Table 1-18
No.
1
M5 connecting studs
2
M10 connecting studs
3
M4 grounding stud
4
M6 grounding stud
Table 1-19
Connections for the terminal box
Terminal
Cable
box type
entry
gk130
1 x Pg29
gk230
1 x Pg29
gk420
1 x Pg36
gk630
2 x M32 x 1.5
gk630
2 x M40 x 1.5
gk630
2 x M50 x 1.5
1) Data according to DIN EN 60204–1 (routing type C, ambient temperature 40_ C)
2) BR/BR2 (terminal strip, only for versions with brake)
3) Dependent on the seal used
 Siemens AG 2004 All rights reserved
Synchronous Servomotors, 1FT6 (PFT6) – 02.04 Edition
Description, refer to Fig. 1-2
Description
Max. cable
Max.
outer
current
3)
1)
diameter
[A]
[mm]
30
36
30
66
37
104
25
112
32
176
41
209
1.8 Electrical connections
No.
Description
5
M10 grounding studs
6
M4 connecting studs
BR
Brake connection
Power
Max. cross–
connec–
section per
tion
phase
2
3 x M4
1 x 6 mm
2
3 x M5
1 x 16 mm
2
4 x M10
1 x 35 mm
2
3 x M10
2 x 16 mm
2
3 x M10
2 x 35 mm
2
3 x M10
2 x 50 mm
Motor Description
Ground
Brake
connec–
connection
2)
tion
2
M4
1.5 mm
2
M4
1.5 mm
2
M6
1.5 mm
M10
–––
M10
–––
M10
–––
1FT6/1-41