Motor Components (Options)
3.1 Thermal motor protection
Caution
!
The integrated temperature sensor protects the synchronous servomotors against
overload conditions:
Shaft height 28 to 48
from shaft height 63
There is no adequate protection at thermally critical load situations, e.g. a high
overload at motor standstill. This is the reason that, for example, a thermal
overcurrent relay must be provided as additional protection.
If an overload condition of 4SM
protection should be provided.
R [kΩ]
Fig. 3-1
1FT6/3-180
lasts for longer than 4s, then additional motor
0
3
2
1
0
0
100
Resistance characteristic of the KTY 84 as a function of the temperature
to 2 S I
and speed <> 0
0 60 K
to 4 S I
and speed <> 0
0 60 K
I
= 2 mA
D
200
 Siemens AG 2004 All rights reserved
Synchronous Servomotors, 1FT6 (PFT6) – 02.04 Edition
ϑ
[°C]
U
300