Installing A Bottom Mounted Unit - Hatco CSUR Série Manuel D'installation

Plaques réfrigérantes encastrables contrôlées à distance
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Installing a Bottom Mounted Unit (CSSBR,
CSSBFR, CSSBX, and CSSBFX Models)
NOTICE
Use caution and avoid hitting condensing unit hoses/lines
when installing unit. Damage caused during installation is
not covered under warranty.
1. Remove the mounting
bracket assembly from
each corner of the cold
shelf. To remove:
a. Remove the two shipping
screws and washers that
attach each mounting
bracket assembly to the
bottom of the unit.
b. Carefully lift the cold
shelf above the shipping
frame, and rotate it far enough to allow the unit to be set
back down on top of the frame (the mounting brackets
will stay on the frame or fall out the bottom). This step
requires two or more people, depending on the unit.
c. Remove the mounting bracket assemblies from the
frame, if necessary.
Accessory
Gasket
Lock Nut
Leveling Bolt
Inside surface of
Inside surface of
mounting bracket
mounting bracket
assembly flush with
assembly flush with
inside of cutout.
inside of cutout.
Bottom
of unit.
Mounting
Bracket
Assembly
Washer
Shipping
Screw
Installing a CSSBFR Model Cold Shelf
2. On each mounting bracket
assembly,
remove
shipping screws and the
triangular shipping bracket
that was used to attach the
mounting bracket assembly
to the bottom of the cold
shelf, and discard.
3. Attach a mounting bracket
assembly to the underside
of the prepared countertop
at each corner of the cutout.
a. Align the u-shaped mounting holes on the mounting
bracket with the two pre-drilled mounting holes on the
underside of the countertop. The inside surface of the
mounting bracket should be vertically flush with the inner
surface of the countertop cutout.
b. Insert appropriate fasteners through the mounting
bracket and into appropriate anchoring devices in the
mounting holes on the underside of the countertop.
Tighten securely.
4. Install the included self-adhesive gasket around the inner,
vertical surface of the countertop cutout.
• The gasket should be positioned 1/4" (6 mm) below the
top surface of the countertop.
NOTE: If the accessory, self-adhesive gasket is not available,
provide a caulk backing around the inner, vertical
surface of the countertop cutout 1/4" (6 mm) below
the top surface of the countertop. This will prevent the
silicone sealant applied later in this procedure from
falling through the gap between the countertop and the
cold shelf.
16
English
Shipping
Bracket
the
Shipping
Screw
Countertop
Cutout
Form No. CSRM-0220

Publicité

Chapitres

Table des Matières
loading

Table des Matières