English
For CWBX and CWBX-S Models:
a. Connect the on-site power supply through the power
input knockout to the POWER IN terminal block.
b. Connect power from the POWER OUT terminal block,
through the power output knockout, to the solenoid
valve on the refrigerated well.
c. Connect the temperature probe wire from the
refrigerated well, through the probe wire inlet, to the
digital temperature controller.
Temperature probe installed here.
Wire from probe connects to control panel
(same for CWBR Models).
CWBX Model Electrical Connections
Installing the Control Panel Remotely
Use the following procedure to install the control panel remotely.
WARNING
Control panel must be mounted in a vertical surface.
Mounting control panel in a horizontal surface may result
in the collection of liquids and lead to electric shock.
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the "Control Panel Cutout and Screw Hole
Dimensions" chart for the cutout dimensions.
Countertop Cutout Dimensions
Width
Model
(A)
CWBR-1
17-1/8" – 18"
CWBX-1
(435 – 457 mm)
CWBR-2
30-1/8" – 31"
CWBX-2
(765 – 787 mm)
CWBR-3
43-1/8" – 44"
CWBX-3
(1095 – 1118 mm)
CWBR-4
56-1/8" – 57"
CWBX-4
(1425 – 1448 mm)
CWBR-5
69-1/8" – 70"
CWBX-5
(1756 – 1778 mm)
CWBR-6
82-1/8" – 83"
CWBX-6
(2086 – 2108 mm)
Form No. CWBRM-0418
Solenoid Valve
Power Input
Depth
(B)
25-3/16" – 26"
CWBR-S1
(640 – 660 mm)
CWBX-S1
CWBR-S2
25-3/16" – 26"
CWBX-S2
(640 – 660 mm)
CWBR-S3
25-3/16" – 26"
CWBX-S3
(640 – 660 mm)
CWBR-S4
25-3/16" – 26"
CWBX-S4
(640 – 660 mm)
25-3/16" – 26"
(640 – 660 mm)
25-3/16" – 26"
(640 – 660 mm)
2. Remove the four trim cover screws from the control panel
and remove the trim cover.
3. Position the control panel into the cutout opening through
the backside.
4. Fasten the control panel to the vertical surface using four
screws (not supplied).
5. Apply a 1/4" (6 mm) bead of NSF-approved silicone sealant
where the trim cover will contact the cabinet surface. Refer
to the "Control Panel Cutout and Screw Hole Dimensions"
illustration for more information.
6. Reinstall the trim cover on the control panel and secure
in position using the four trim cover screws. Make sure to
embed the trim cover edge into the silicone.
7/16"
(11 mm)
3/8"
(9 mm)
Control Panel Cutout and Screw Hole Dimensions
NOTE: Make sure the width of the control panel cutout does
not exceed the above dimension.
Width
Model
(A)
25-1/4" – 26-1/16"
(641 – 662 mm)
46-1/4" – 47-15/16"
(1175 – 1196 mm)
67-5/16" – 68-1/8"
(1710 – 1731 mm)
88-3/8" – 89-1/4"
(2245 – 2266 mm)
11
INSTALLATION
Silicone Sealant
1-1/16"
(27 mm)
5-5/8"
(143 mm)
3-1/2"
(89 mm)
7-7/16"
(189 mm)
7-3/4"
(196 mm)
Depth
(B)
17-1/16"–17-15/16"
(433–456 mm)
17-1/16" – 17-15/16"
(433 – 456 mm)
17-1/16" – 17-15/16"
(433 – 456 mm)
17-1/16" – 17-15/16"
(433 – 456 mm)
A
B