Preparing The Installation Site; Installing The Unit - Hatco FTB Série Manuel D'installation Et D'utilisation

Plans réfrigérés de libre service
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Moving the Condensing Unit
This procedure can be performed on FTB-2, FTB-3, FTB-S2,
and FTB-S3 models only.
1. Remove the four mounting screws that secure the
condensing unit support frame to the underside of the frost
top enclosure.
2. move the condensing unit to the desired position. The
condensing unit can be installed in several positions along
the bottom of the frost top enclosure using pre-drilled holes
at 6-1/2" (165 mm) increments (3" [76 mm] increments for
FTB-2).
3. Reattach the condensing unit support frame to the frost top
enclosure using the four mounting screws.
Condensing Unit in End Position
Mounting
Screw
Condensing Unit Moved to Opposite End
moving a Condensing Unit

Preparing the Installation Site

1. Cut the appropriate opening in the countertop for the unit
being installed. Refer to "Countertop Cutout Dimensions"
in this section.
2. If installing the control panel remotely, cut and drill the
appropriate holes in the vertical surface where the control
panel will be installed. Refer to the "Installing the Control
Panel Remotely" procedure for cutout dimensions.
3. make structural modifications or add bracing underneath
the countertop to ensure the countertop will support the
weight of the unit and its contents. make sure a minimum
2" (51 mm) clearance will be available between the
condensing unit and any interior surface.
NOTE: The countertop must be level to ensure proper draining
of the frost top enclosure.
4. Cut the required openings in the cabinetry to provide
proper ventilation to the condensing unit as well as access
to the control panel. Two openings, each with a minimum
size of 12" x 12"/144 square inches (31 x 31 cm/
961 square cm), are required. For proper operation, one of
these ventilation openings must be in front of the
condenser coils with the other on the opposite side.
Louvered or grill-style panels should be installed in the
openings to protect the condensing unit.
5. make sure a grounded electrical receptacle of the correct
voltage, size, and plug configuration is within 6' (1829 mm)
of the mounting location for the control panel. See the
SPECIFICATIONS section for details.

Installing the Unit

Use caution and avoid hitting condensing unit hoses/lines
when installing unit. Damage caused during installation is
not covered under warranty.
1. Lift the unit out of the wooden shipping frame and carefully
lower it into the countertop cutout. This step requires two or
more people, depending on the unit.
2. Apply National Sanitation Foundation-approved (NSF-
approved) silicone sealant around the edge of the unit to
seal it to the countertop.
3. Install the control panel in the desired location.
• The control panel can be installed on one of three sides
of the condensing unit support frame. Do not install the
control panel in front of the condenser coils.
• The control panel can be installed remotely within 48"
(1219 mm) of the condensing unit. Refer to the "Installing
the Control Panel Remotely" procedure in this section.
4. Connect the 1" NPT drain fitting to a trap and drain line
(except FTB-3/4 and -1 models). If a trap and drain line are
not available, a catch pan (not supplied) must be used
under the drain fitting to contain water draining from the
frost top enclosure.
NOTE: Consult a qualified plumber for proper trap and drain
installation that conforms to local plumbing codes.
l o w
l o w
A i r F
A i r F
Ventilation/Control
Access Openings
(on opposite side
of cabinet also)
Installing a FTB-2
5. Clean the frost top enclosure thoroughly in preparation for
initial operation. Refer to the mAINTENANCE section for
proper cleaning procedures.
NOTE: If a catch pan is used underneath the drain fitting, make
sure the pan is emptied regularly to prevent over-
flowing.
6. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
8
English
NOTICE
Full-Size
Sheet Pan
e n s e
C o n d
Countertop
Cutout
Form No. FTBm-1015
l s
r C o i

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Ftb-s sérieFtb-2Ftb-s2Ftb-3-4Ftb-1Ftb-3 ... Afficher tout

Table des Matières