Installing an Auto-Fill Unit
Use the following procedure to install a unit equipped with the
auto-Fill option. Refer to "Water Supply Specifications" in the
SPECIFICaTIONS section of this manual for water supply
requirements.
1. apply Teflon tape to the threads of the street elbow on the
fill tube assembly.
2. Connect the street elbow to the auto-Fill fitting located on
the outside of the well.
3. Connect the other end of the fill tube assembly to the fill
valve nipple in the control enclosure and secure using the
hose clamp. (Disassemble the control enclosure trim cover
to access the nipple.)
4. Connect the on-site water supply line to the 1/4" NPT water
inlet fitting on the control enclosure.
5. Turn on the water supply and check for leaks.
Water Inlet
Fitting
Fill Tube
Assembly
Installing an auto-Fill Unit (HWBIB-FULDa shown)
Installing A Drain Assembly
after installing a drain-equipped unit into the countertop, use
the following procedure to connect the unit to the on-site drain
line.
CAUTION
BURN HAzARD: Drain water may reach temperatures in
excess of 93°C (200°F). Use appropriate plumbing
materials when installing drain.
NOTE: Consult a licensed plumbing contractor for proper drain
installation that conforms to local plumbing codes.
NOTE: Approved air gap or other back-flow prevention device
must be installed by a licensed plumber, if required.
1. Connect drain pipe (supplied by others) from the 3/4" NPT
drain fitting on the bottom of the unit to a 3/4" drain valve
(supplied by others or available as an accessory from
Hatco — refer to the OPTIONS aND aCCESSORIES
section).
Form No. HWBCEM1-0515
Auto-Fill Fitting
Street Elbow
Water
Inlet
Fitting
Fill
Valve
Nipple
Hose
Clamp
Fill
Tube
NOTE: The drain valve must be installed in an easily
accessible location for the operator.
2. Connect the drain valve to the on-site drain line (supplied
by others).
3/4" Drain Fitting
3/4" Drain Valve
Installing A Bottom Mount Unit
Installation of a bottom mount unit requires custom fabrication
of the countertop by a qualified and experienced installer. Use
the following information as guidelines for one method of
installing a bottom mount unit.
• Create the countertop cutout with turned-down flanges on
all four sides. These flanges should be positioned on the
inside of the well for installation.
Front View
Turned-Down Flange
222 mm
(8-3/4")
306 mm
(12-1/32")
Side View
Turned-Down Flange
426 mm
(16-3/4")
509 mm
(20-1/32")
Suggested Turned-Down Flange Dimensions
•. apply silicone sealant to the top edge of the well before
installation.
• Secure the unit to the countertop by installing mounting
screws (not supplied) through the turned-down flanges and
into the top rim of the well.
Turned-Down
Flanges
Installing Bottom Mount Unit
19
INSTALLATION
Drain Connection
Countertop
Countertop
28 mm
(1-3/32")
Countertop
Mounting
Screw
(not supplied)
To drain