Installing A Top Mounted Unit; Countertop Cutout Dimensions-Top Mounted Units - Hatco CSUR Série Manuel D'installation

Plaques réfrigérantes encastrables contrôlées à distance
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Installing a Top Mounted Unit (CSBFR and
CSBFX Models)
NOTICE
Use caution and avoid hitting condensing unit hoses/lines
when installing unit. Damage caused during installation is
not covered under warranty.
1. Apply a bead of National Sanitation Foundation (NSF)-
approved silicone sealant on the top edge of the countertop
cutout and the underside of the trim mounting ring. The
sealant must be rated for use at temperatures between
-10°F (-23°C) and 250°F (121°C).
2. Lift the cold shelf out of the shipping frame and carefully
lower it into the countertop cutout. This step requires two or
more people.
NOTE: If excessive condensation appears underneath the
countertop during operation, apply polyurethane-based
foam sealant in the gap between the underside of the
countertop and the shelf.
3. Install the control box in the desired location.
• The control box can be installed remotely within 6'
(1829 mm) of the shelf. Refer to the "Installing the
Remote Control Box" procedure in this section.
DO NOT tip unit/mounting surface after final installation.
Unit is free-floating and could fall out if tipped—for
permanent, horizontal installations only.
Countertop Cutout Dimensions — Top Mounted Units
Model
Width (A)
CSBFR-24-F
24-5/8"–25"
CSBFX-24-F
(625–635 mm)
CSBFR-24-I
24-5/8"–25"
CSBFX-24-I
(625–635 mm)
CSBFR-24-S
24-5/8"–25"
CSBFX-24-S
(625–635 mm)
CSBFR-36-F
36-5/8"–37"
CSBFX-36-F
(930–940 mm)
CSBFR-36-I
36-5/8"–37"
CSBFX-36-I
(930–940 mm)
CSBFR-36-S
36-5/8"–37"
CSBFX-36-S
(930–940 mm)
CSBFR-48-F
48-5/8"–49"
CSBFX-48-F
(1234–1245 mm)
CSBFR-48-I
48-5/8"–49"
CSBFX-48-I
(1234–1245 mm)
CSBFR-48-S
48-5/8"–49"
CSBFX-48-S
(1234–1245 mm)
CAUTION
Depth (B)
16-1/8"–16-1/2"
(409–419 mm)
20-1/8"–20-1/2"
(511–521 mm)
24-5/8"–25"
(625–635 mm)
16-1/8"–16-1/2"
(409–419 mm)
20-1/8"–20-1/2"
(511–521 mm)
24-5/8"–25"
(625–635 mm)
16-1/8"–16-1/2"
(409–419 mm)
20-1/8"–20-1/2"
(511–521 mm)
24-5/8"–25"
(625–635 mm)
4. For CSBFR models, install the condensing unit in the
desired location. Refer to the SPECIFICATION section for
installation dimensions.
• Make sure the installation site provides a level, stable
surface for mounting the condensing unit.
• Make sure the installation site offers continuous air flow
ventilation to the condensing unit.
• Make sure there is a minimum of 6" (152 mm) of space
between all sides of the condensing unit and any
combustible surface.
5. Have qualified installers perform the "Connecting the
Components" procedure in this section.
6. Clean the cold surface thoroughly in preparation for initial
operation. Refer to the MAINTENANCE section for proper
cleaning procedures.
Installing a CSBFR Model Cold Shelf
14
English
Countertop
Cutout
B
A
Form No. CSRM-0220