Locating pump:
①Set the pump on flat area, and near water source.
②Connect suction hose and delivery hose to the pump securely. Put end
of suction hose in water source.
The suction hose must have a strainer and a basket.
③When water is discharged through branch pipe and nozzle, following di-
ameter of nozzles is recommended.
Model
VC85BS
VC82ASE
VC72AS
VC52AS
Remark:*The largest nozzle dia. at 3m of suction head.
Starting engine:
Wear proper hearing protection during operation.
(1) Open the fuel cock lever by turning
it downward.
ENGINE START
Largest Nozzle Dia. (mm) *
Twin outlet
25
25
-
-
CAUTION
(2) Set the throttle dial at
- 17 -
Single outlet
36
36
36
36
START ▼ SUCTION position.
Throttle dial
8