OK Monitor makes it easy to visually check status of necessary items for
pump operation on control panel.
When the monitor lamps are off, it shows there has no any troubles on each
function. When the monitor lamps are on or blinking, the function in particu-
lar does not work properly.
(1) Countermeasuring when the monitor lamp is ON.
It is necessary to take a countermeasure if the lamp is on when turning
the main switch to the position of "Operation".
6
Monitor lamp
Fuel
Engine oil
Overheat
Suction failure
(for model VC85BS)
USE OF OK MONITOR
Lamp ON
Level of fuel has dropped
below
one
third
of
capacity.
Oil level is below quarter of oil
tank capacity.
Engine stops caused by lack
of cooling water.
Under "Auto-suction" mode, if
the pump cannot properly
complete priming water within
15 seconds, the engine will
stop.
- 14 -
Action required
Supply fuel.
tank
Supply 2 stroke engine oil.
VC82ASE, VC72AS, VC52AS
Check the cause and reme-
dy it. Turn the overheat sen-
sor switch to "OFF" position
and start the engine. After
confirming the lamp is off,
return the switch to "ON" po-
sition.
VC85BS
Remedy the cause and re-
start engine. Engine may be
shut down unless engine
temperature goes down in
30seconds after restarting.
Restart
after
cause.
(See TROUBLE SHOOTING.)
remedy
the