INSTALLATION
Safety
INSTALLATION
7.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1
General safety instructions
We guarantee trouble-free function and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
7.2
Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
8.
Appliance description
8.1
Standard delivery
Delivered with the appliance:
- Thermometer (delivered inside the control panel)
- Cold water inlet pipe with flat gasket
- Adhesive rose for DHW circulation line
- Adaptor with flat gasket for the connection of a DHW circula-
tion line
- Plastic cap
- Adjustable feet
8.2
Accessories
Required accessories
Depending on the static pressure, safety assemblies and pressure
reducing valves are available. These type-tested safety assemblies
protect the appliance against unacceptable excess pressure.
Further accessories
If it is not possible to fit an anode rod from above, install a seg-
mented signal anode.
22
| SHW S
9.
Preparations
9.1
Installation site
Always install the appliance in a room free from the risk of frost
and near the draw-off point.
f Use the adjustable feet to compensate for any unevenness in
f
the floor.
9.2
Transport
Material damage
!
We recommend removing the cylinder casing during
transport to the installation location, to prevent it from
becoming dirty or damaged (see chapter "Installation /
Fitting the cylinder casing and DHW circulation line if
required").
10. Installation
10.1 Fitting the cylinder casing and DHW circulation
line if required
Note
Fit the cylinder casing with cover before making the water
connection and, if necessary, the DHW circulation line or
the flanged immersion heater.
The plinth trim should be fitted after the tightness check.
A DHW circulation line can be fitted to the "DHW circulation"
connection (see chapter "Specification / Dimensions and connec-
tions"). Alternatively, the "DHW circulation" connection can be
used to connect a thermometer.
Dismantling
f Remove the cover and the plinth trim of the cylinder casing
f
one after the other.
f Pull off the temperature selector on the flanged immersion
f
heater.
f Remove the control panel cover and cable grommet.
f
f Remove the cylinder casing.
f
www.stiebel-eltron.com