Specification
Dual circuit operation, dual meter measurement with power
supply utility contact
1/N/PE ~ 230 V
3/N/PE ~ 400 V
PE
K1
K2
4
L1
L2
L3
N
K1 Contactor 1
K2 Contactor 2
1 Connections also required for 3/N/PE ~ 400 V
2 Power supply utility contact
3 Off-peak tariff meter
4 Peak tariff meter
Ensure connection to the same phase.

16.3 Details on energy consumption

Product datasheet: Conventional water heaters to regulation (EU) no. 814/2013
Manufacturer
Load profile
Energy efficiency class
Energy conversion efficiency
Annual power consumption
Default temperature setting
Sound power level
Option for exclusive operation during off-peak periods
Special information on measuring efficiency
Smart function
Cylinder capacity
Mixed water volume at 40 °C
Daily power consumption
30
| SHW S
5
K2
K1

16.4 Heat-up diagram

The heat-up time depends on the cylinder capacity, cold water
inlet temperature and heating output.
At 10 °C cold water temperature and temperature setting "E":
12
10
8
1
6
4
2
X Nominal capacity [I]
Y Duration [h]
1 2 kW
2 3 kW
3 4 kW
4 6 kW

16.5 Fault conditions

2
In the event of a fault, temperatures of up to 95 °C at 0.6 MPa
3
can occur.
SHW 200 S
182120
STIEBEL ELTRON
%
kWh
4294
°C
dB(A)
l
l
kWh
19.699
300
400
SHW 300 S
182121
STIEBEL ELTRON
XL
XL
C
C
39
39
4311
60
60
15
15
-
-
-
-
200
300
392
582
19.796
www.stiebel-eltron.com
1
2
3
4
SHW 400 S
182122
STIEBEL ELTRON
XL
C
39
4268
60
15
-
-
400
768