INSTALLATION
Safety
Nr.: ...... - .... - ......
Typ:
SHU...
INSTALLATION
6.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1
General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
6.2
Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
6.3
Information on the safety assembly
Material losses
!
Never exceed the operating pressure.
Material losses
!
Install a type-tested safety valve, or safety assembly con-
taining such a safety valve, in the cold water supply line.
Material losses
!
Route the drain pipe of the safety assembly with a slope
and leave it open to the atmosphere.
Material losses
!
The safety equipment requires regular maintenance and
activation (see installation instructions of the safety as-
sembly).
If using a plastic stench trap (e.g. DN 40 for the sink), there is no
need for the SVMT immersion pipe. Connect the overflow funnel,
e.g. using the washing machine connection.
14
| SHU 5
7.
Appliance description
The sealed unvented (pressurised) appliance is only suitable for
undersink installation. The appliance is intended for heating cold
water and for supplying one or several draw-off points.
The appliance may only be installed with pressure taps in con-
junction with the SVMT safety assembly (see chapter "Installation /
Appliance description / Required accessories").
7.1
Standard delivery
Delivered with the appliance are the following:
- Wall mounting bracket
7.2
Required accessories
The following accessories are available for sealed unvented op-
eration:
- SVMT safety assembly for undersink installation
- Water distribution tees
8.
Preparation
Water installation
A safety assembly is required.
Taps/valves
Only install pressure taps in conjunction with the SVMT safety
assembly.
8.1
Installation site
Material losses
!
Install the appliance in a room free from the risk of frost.
Material losses
!
Mount the appliance on the wall. The wall must have a
sufficient load-bearing capacity.
Material losses
!
The appliance is only suitable for undersink installation.
The water connections of the appliance point upwards.
Note
Ensure that the appliance is freely accessible for main-
tenance work.
Always install the appliance vertically and near the draw-off point.