Power Supply - Stiebel Eltron SHW 200 S Utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
INSTALLATION
Installation
10.4.2 Connection
f Flush the pipes thoroughly.
f
The max. permissible pressure must not be exceeded (see chapter
"Specification / Data table").
ff Install a type-tested safety valve in the cold water supply
line. Please note that, depending on the static pressure, you
may also need a pressure reducing valve.
f Fit the DHW outlet pipe and the cold water inlet pipe. Con-
f
nect the hydraulic connections with flat gaskets.
1
1 Cold water connection
2 Cold water supply pipe
f Connect the cold water supply directly to the cylinder or with
f
the connecting pipe routed between the cylinder feet.
f During fitting, counterhold the fitting with an open-ended
f
spanner (size 36).
f Check the rigidity of the connecting pipe and secure it further
f
if required.
ff Size the drain so that water can drain off unimpeded when
the safety valve is fully opened.
ff Fit the discharge pipe of the safety valve with a constant
downward slope and in a room free from the risk of frost.
ff The safety valve discharge aperture must remain open to the
atmosphere.
24
| SHW S

10.5 Power supply

WARNING Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
WARNING Electrocution
The connection to the power supply is only permissible
as a permanent connection in conjunction with the re-
movable cable entry. Ensure that the appliance can be
separated from the power supply by an isolator that dis-
connects all poles with at least 3 mm contact separation.
WARNING Electrocution
Ensure that the appliance is earthed.
WARNING Electrocution
Install a residual current device (RCD).
2
Material damage
!
Observe the type plate. The specified voltage must match
the mains voltage.
f Pull off the temperature selector.
f
f Undo the screws at the bottom of the control panel cover and
f
remove the cover.
f Prepare the power cable and feed it through the cable grom-
f
met into the control panel. Select a cable with a cross-section
suited to the load of the appliance.
Note
If you connect the appliance for 3 kW output, two heating
elements are connected in series and the surface load is
reduced. This can significantly prolong the service life of
the electric heating elements, particularly in areas with
a water hardness level of 14 °dH or higher.
f Connect the required load in accordance with the connection
f
examples (see chapter "Specification / Wiring diagrams and
connections").
f Fit the control panel cover.
f
f Push on the temperature selector.
f
f If the power supply utility does not permit rapid heating,
f
cover the pushbutton with the plastic cap provided.
f Use a ballpoint pen to mark the selected connected load and
f
voltage on the type plate.
www.stiebel-eltron.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Shw 300 sShw 400 s

Table des Matières