Switching Off
Turn the master switch to 0 and turn
N
off the water supply
Actuate the spray gun until water
N
only drips from the spray head (the
machine is now depressurized)
Release trigger
N
1
Press the safety latch (1) in the
N
direction of the arrow – the spray
gun is locked to prevent inadvertent
operation
Unplug the power plug from the
N
socket
Disconnect water intake hose from
N
machine and water supply
RE 361, RE 361 PLUS, RE 461, RE 461 PLUS, RE 471 PLUS
After use
Roll the high-pressure hose and
N
power cable up on the brackets
provided for this purpose – see
"Main parts of the machine"
Storing the Machine
Store the machine in a dry room where it
is protected from frost.
If protection from frost cannot be
guaranteed, draw glycol-based
antifreeze – like that used in motor
vehicles – into the pump:
Insert water intake hose in container
N
with antifreeze
Insert spray gun without spray lance
N
in the same container
Switch on the machine with the
N
spray gun open
Actuate the spray gun until a
N
uniform jet emerges
Keep leftover antifreeze in a sealed
N
container