INSTRUCTIONS FOR USE
EN
Self-diagnostics
The machine can perform self-diagnostics to check the LEDs on the control panel and make sure the encoder
reads correctly.
To perform this operation, view the SETUP menu.
In the self-diagnostics sequence, all the LEDs on the panel light up for a few seconds, in order to check
operation. When the LEDs go out, the machine automatically moves on to the encoder reading phase. When
the wheel is turned manually (forwards and backwards), the display shows its exact position.
The value lies between 0 (zero) and 255.
Calibration
To calibrate the machine, proceed as follows:
1. Fit an average size wheel with a steel rim onto the shaft. Example: 6" x 15" (± 1").
2. Set the mounted wheel measurements as described in section SETTING WHEEL DIMENSIONS.
3. Display the SETUP menu:
4. Press
to view the CALIBRATION function.
5. Add a standard weight of 60 g to the outer side, in any position.
6. Shift the standard weight from the outside to the inside, keeping the same position.
7. Turn the wheel until the standard weight is at the top (12 o'clock).
8. End of calibration
To cancel calibration at any time, press
28
Perform a manual spin
Perform a manual spin
Perform a manual spin