PROGRAMMING PROCEDURE (Setting the programmer, the current sensor and the work times)
Before commencing make sure that the doors/gates are closed, the LCD display is off and the LEDS L10, L11, L12 are all lit.
LED L4 and L6 (if the closing direction travel limits for leaves 1 and 2 have been installed) are off (closing travel limit activated)
DS1
PRESS THE PROG BUTTON FOR MORE THAN
4 SECONDS: THE PARAMETER DEFINITION
LETTER "d" WILL APPEAR ON THE DISPLAY
(STAGE "A")
AFTER 1 SECOND THE DIGIT "1" WILL APPEAR (FIRST PROGRAMMING
STEP). THIS NUMBER CAN BE EITHER FLASHING OR FIXED
ACTIVE
FUNCTION
PRESS
Single
PROG
motor
PRESS SEL
Hinged
PRESS
PROG
gates
PRESS SEL
Binding posts 7,8
PRESS
courtesy light
PROG
SEL
Electric lock
PRESS
enabled
PROG
PRESS SEL
TD:
PRESS
open-close
PROG
Note 1
PRESS SEL
Automatic
PRESS
reclosing
PROG
enabled
PRESS SEL
Preflashing
PRESS
PROG
enabled
PRESS SEL
Motor 1
PRESS
travel limit
PROG
enabled
PRESS SEL
Motor 2
PRESS
travel limit
PROG
enabled
PRESS SEL
Warning lights
PRESS
with onboard
PROG
electronics
PRESS SEL
Deceleration
PRESS
enabled
PROG
PRESS SEL
Non flashing
PRESS
indicator
PROG
light
PRESS SEL
FTC_I
enabled with
PRESS
gate blocked
PROG
PRESS SEL
Nota 3
PRESS
SEL
WAIT FOR ABOUT 20 SECONDS WITHOUT PRESSING ANY BUTTONS: THE
PROGRAMMER WILL SAVE THE PARAMETERS SET UP TO NOW AND WILL
QUIT PROGRAMMING.
Note 1 Travel direction inversion only active during the closing stage.
Note 2 The indicator light flashes slowly during opening, quickly during closing,
remains open when the gate is not completely closed, and is off when the
gate is completely closed.
Note 3 If the photoelectric cell is in alarm and the gate is blocked no movement
commands will be accepted (not even in the opening direction).
The R1, R2 and R3
selection must be carried
ACTIVE
out even if deceleration is
FUNCTION
excluded: The time during
Double
which the electrical sensor
motor
works as a travel limit in the
last few seconds of
movement must be decided
upon.
Sliding
You are advised to set a
gates
time of 4,5 seconds.
The choice should be made
to enable a smooth stop
with slow speed only being
Binding posts 7,8
used where absolutely
CH2 radio control
necessary.
Electric lock
disabled
TD:
open-block
close-block
Automatic
reclosing
disabled
Preflashing
disabled
Motor 1
travel limit
disabled
The programmer checks
the electrical input to the
Motor 2
motor, detecting any
travel limit
eventual increase in effort
disabled
above the normal operating
limits. To guarantee correct
operation even under
Warning lights
various climatic and
activated
mechanical conditions, the
by PRG
programmer recalibrates
itself each time it receives
an opening command from
Deceleration
the "completely closed"
disabled
position. This allows the
system to detect any
increase in effort which
wasn't present during
Flashing
programming and to
indicator light
compensate so that the
Note 2
force required to block the
door remains constant, so
FTC_I
guaranteeing optimum
enabled only
operation (see
during closing
"compensation of the
electrical sensors" page 12.
PRESS
PROG
PRESSING "PROG" WILL TAKE YOU TO STAGE "B". PROGRAMMING THE
DECELERATION TIMES. THE VALUES RANGE FROM 1 TO 3.
ALTERNATING
Attention!
PRESS
SEL
ALTERNATING
PRESS
SEL
ALTERNATING
PRESS
SEL
PRESS
PROG
WAIT FOR ABOUT 20 SECONDS WITHOUT PRESSING ANY BUTTONS: THE
PROGRAMMER WILL SAVE THE PARAMETERS SET UP TO NOW AND WILL
QUIT PROGRAMMING.
PRESSING "PROG" WILL TAKE YOU TO STAGE "C". PROGRAMMING THE
CURRENT SENSOR. THE VALUES RANGE FROM 1 TO 3.
ALTERNATING
Attention
PRESS
SEL
ALTERNATING
PRESS
SEL
ALTERNATING
PRESS
SEL
PRESS
PROG
WAIT FOR ABOUT 20 SECONDS WITHOUT PRESSING ANY BUTTONS: THE
PROGRAMMER WILL SAVE THE PARAMETERS SET UP TO NOW AND WILL
QUIT PROGRAMMING.
PRESSING "PROG" WILL TAKE YOU TO THE FINAL STAGE "D". PROGRAMMING
THE WORK TIMES.
10
FIXED
VALUE
PRESS
selection
PROG
3 seconds
FIXED
VALUE
selection
PRESS
4,5 seconds
PROG
FIXED
VALUE
selection
PRESS
6 seconds
PROG
PRESS
SEL
1...20 s
FIXED
VALUE
PRESS
minimum
PROG
torque
FIXED
VALUE
medium
PRESS
torque
PROG
FIXED
VALUE
maximum
PRESS
torque
PROG
PRESS
SEL
1...20 s
CONTINUE ON PAGE 11

Publicité