Intended Use - DeVilbiss Healthcare drive Casalift 18001 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Foreword
Components and assembly of the Casalift
Introduction
Assembly – Inserting the support
1
4
Foreword
Components and assembly of the Casalift
1.1
Introduction
The Casalift 180 is a lightweight and versatile lift device for use in patient and
Support bracket
geriatric care situations. Use of the lift is facilitated considerably by its spreading
travel leg design. After use, or for transport by car, it can be dismantled.
This manual was produced based upon the information available on the design
and operation of the Casalift which was available at time of printing. We reserve
Control module
the right to make changes due to technical advances.
with battery
Should you have any questions concerning the Casalift, please contact your spe-
Lifting motor
cialist Days Healthcare dealer (see dealer's stamp on the back of the envelope).
Chassis
1.2

Intended use

Castors
The Casalift 180 should be use exclusively for the purpose of lifting and moving
persons in need of care. It is only designed to move patients over short
distances.
Improper use will lead to the exclusion of the manufacturer's liability.
The Casalift may only be used by persons who have received instruction from the
owner, and under consideration of the condition of the patient being transport-
4.1
Assembly – Inserting the support
ed. In borderline cases, or if in doubt, consult the attending doctor.
Restriction on use!
Patients who are heavier than 180 kg must not be lifted with the Casalift.
1.3
Information on the operating manual
A
1.3.1
Symbols used in the operating manual
The following symbols are used in the operating manual to identify particular
hazards in using the product or information to simplify usage.
Caution!
This symbol identifies safety instructions which highlight risks in using the prod-
uct.
1. Position the chassis (A) and lock all wheel brakes on the Casalift (see
page 28).
2. Insert the support (B) into the receptacle on the chassis.
Caution!
This symbol identifies safety instructions which highlight risks of crushing and
3. Tighten the locking screws (C) in a clockwise direction.
trapping when using the product.
GB – 20
GB – 24
26
Boom
Operating controls
Support
Sliding handle
Castors
with brake
Spreading motor
B
C
Casalift 140E / 180E – 15.10.2010
Casalift 140E / 180E – 15.10.2010
Casalift 180 - SEPTEMBER 2017
Safety devices
Safety
Assembly – Connecting the spreading motor
Safety instructions
4.2
Assembly – Connecting the spreading motor
Note
Under this symbol, you can find helpful information on using the product.
1.3.2
Information on the operating manual
Carefully read through the operating manual before assembling the Casalift and
A
bring it into service!
Make sure that:
all persons who are to use the Casalift have read the operating manual.
1. Plug connector (A) into the socket on the control module.
all persons charged with setting up or maintaining the Casalift always have
The sealing ring on the connector must not be damaged while being
access to the operating manual.
plugged in.
Damage caused through a failure to follow the information in the operating
manual is excluded from any and all warranty claims.
2. Hook the cable for the operating controls into the cord grip (B).
The illustrations which appear in this operating manual are only examples of
how to use Days Healthcare patient lifts, and may differ from your actual model.
5
Safety devices
2
Safety
5.1
Safety devices – EMERGENCY STOP button
2.1
Switching on
Safety instructions
Press the EMERGENCY STOP button (A).
2.1.1
Safety instructions – General
After the EMERGENCY STOP button
is pressed, the lifting motor stops
immediately. It can no longer be ac-
Risk of accident!
tivated with the operating control.
Only use the Casalift for its intended use. The Casalift is not a piece of gym-
nastics or playground equipment.
Switching off
Only use the Casalift if it is in a technically sound condition.
Turn the EMERGENCY STOP button
to the right (B).
Only use slings, sling seats or reclined slings which are in perfect condition. Replace
sling systems which are damaged or heavily worn immediately!
The EMERGENCY STOP button is
unlocked. The lift is ready for use
All faults which have a bearing on the function and safety of the Casalift
again.
must be rectified without delay by a specialist dealer.
5.2
Safety devices – Emergency lowering function (electric)
2.1.2
Safety instructions – Assembly
The boom of the Casalift can be lowered
electrically if the operating control fails.
Risk of trapping! Risk of crushing!
There is an increased risk of trapping and crushing at all joints of the Casalift.
Lowering the boom
While assembling the product, pay particular attention to these danger
Press button (A) on the control mod-
points.
ule (e.g. with a pen).
The boom slowly lowers.
Casalift 140E / 180E – 15.10.2010
Casalift 140E / 180E – 15.10.2010
Casalift 180 - SEPTEMBER 2017
B
A
B
A
GB – 25
GB – 21
27

Publicité

Table des Matières
loading

Table des Matières