5. Instructions before use

A. Make sure the control panel type EAZ CC is
connected to the three-phase mains by an
authorized electrician. Use only SKF control
cabinets to avoid damage in the EAZ induction
heater.
B. Make sure that the cabinet is placed on a solid
base and it is stable.
C. To obtain the full heating capacity of the coil
assure that the cable is connected without
loops.
D. Check for damages before use, specially the
sleeve and the power cables. The cables may
get damaged due to the compression or to the
high temperatures.
E. Connect the cable for the overheating protection
of the heater to the control cabinet. Do the
same with the temperature probe extension
cable and the temperature probe itself.
Fig.8 – Adjust the length of the temperature probe cable
to the minimum possible to avoid damages on the
probe itself
F.
With the door of the control panel closed, the
safety locks can now be pushed in with the key.
G. The device is ready for use. The main switch can
now be turned to the on position. This will start
the Graphic User Interface, but it won't power
the EAZ coil.
H. In case that the door of the panel is open, the
main switch cannot be turned on and therefore
no current can pass by. Do not force the main
switch stud with the door open.
I.
Let the EAZ acclimate when there is a
temperature change. Use only inside of
buildings.
EN