Periodic Maintenance - Mecafer MF6500E Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
2 - AC APPLICATION (DUAL VOLTAGE TYPE) (FIG. 3/B)
(OPTION)
(a) Select the correct voltage using the AC OUTPUT SELECT
SWITCH to the same as the rating for the appliance.
(b) Operate in the same way as step (a) through step (d) of
single voltage type.
NOTE:
Voltmeter always indicates the lower voltage
whichever the AC OUTPUT SELECT SWITCH is set.
3 - DC APPLICATION (OPTION)
This usage is applicable to 12V battery charging only.
(a) Charging instruction for battery
• Disconnect the leads of the battery.
• Loosen the battery top up caps to prevent the build up of
pressure during chatrging.
• If the battery fluid level is low , top up the battery with distilled
water to the upper limit,.
• Measure the specific gravity for the battery fluid by using the
hydrometer, and calculate the charging time in accordance
with the table shown on right side.
• The specific gravity for the fully charged battery shall be
within 1.26 to 1.28.
(b) Connect the DC output socket and to the battery terminals
using the charging leadsMake sure that the leads are
connected the correct way round (+) and (-) polarity.
(c) The DC circuit breaker should to be set to the «ON»
position.
3 - STOPPING THE ENGINE (PIC. 14)
1. Turn off the power to the electric equipment or unplug the
mains lead from socket of the generator. Turn the AC switch
to «OFF».
2. Turn the engine switch to «OFF».
3. Turn the fuel cock lever to «OFF».
4 - BATTERY (NOT INCLUDED) CONNECTION FOR
ELECTRIC STARTING SYSTEM
(ONLY FOR MODELS NPEGG3800/5200/6000/7500)
1. REPLENISHING THE BATTERY FLUID
Check the fluid level. The level should be between the upper
and lower level marks.
Add only distilled water if necessary.

5 - PERIODIC MAINTENANCE

1) MAINTENANCE CHART
Regular maintenance is important for the best performance and safe operation.
Warning: Use protective gloves for the following operations.
ITEM
REMARKS
Check condition adjust gap and
Spark Plug
clean.
Replace if necessary.
Check oil level
Engine Oil
Replace
SPECIFIC GRAVITY AND CHARGING TIME CHART
BATTERY CAPACITY
1. 30AH 20 HR
2. 35AH 20 HR
3. 47AH 20 HR
2. BATTERY STORE
Remove the battery and charge it. Store it in a dry place
and recharge it once a month. Do not store the battery in an
excessively warm or cold place.
3. RECOMMENDED BATTERY
Recommended battery: 12V/26A·h
4. OPERATIONS (PIC. 22)
Clamp the wires (included) to the generator. Black wire (-) to
Earth (A) and red wire (+) to the starting motor (B).
Clamp the red wire to the positive (+) terminal and the black
wire to the negative (-) terminal of the battery. Do not reverse
these positions.
Be sure the battery is installed on the battery mount tray
securely.
Perform "Starting the Engine" actions (Chapter 4 – Operation).
With this system there's no need to use the recoil starter
handle, to start the generator just turn the key of the engine
switch (C) to the position "START".
Pre -
Initial
operation
1 month
check (daily)
or 20 Hr
35
Charging time (Hours)
Every
Every
3 months
6 months
or 50Hr
or 100Hr
GB
Every
12 months
or 300Hr

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mf3800450138450165

Table des Matières